Architects, engineering firms, project managers

Specifying a Tiileri masonry heater

All six Tiileri models fall under standard EN 15250:2007 and are documented by their manufacturer. This page brings together the data that can already be published; the manufacturer’s documentation is sent to you on request, until the full specifiers’ area is available.

Data that can be published so far

ModelCatalogue weightNominal outputEfficiency (DoP)Safety distances (DoP)Declaration of performance
HeidiHeidi450 kg8.2 kW[TO BE CONFIRMED]Below the cooking surface: 50 mm at the back and sides. Above the cooking surface: 500 mm at the sides, 1,000 mm upwards. 50 mm to the floorRRF-50 23 6334 (shared with the Helmi)
HelmiHelmi850 kg8.2 kW77%Below the cooking surface: 50 mm at the back and sides. Above the cooking surface: 500 mm at the sides, 1,000 mm upwardsRRF-50 23 6334
AidaAida1,130 kg (h. 1800)1.4 kW91%50 mm at the back, 50 mm at the sides, 150 mm aboveRRF-50 21 5712
AinoAino1,190 kg (h. 1950)1.4 kW91%[TO BE CONFIRMED]RRF-50 21 5712
SofiaSofia1,950 to 1,980 kg[OUTPUT: TO BE CONFIRMED]88%50 mm at the back, 50 mm at the sides, 150 mm aboveRRF-50 21 5713
AmandaAmanda2,110 to 2,240 kg[OUTPUT: TO BE CONFIRMED]88%50 mm at the back, 50 mm at the sides, 150 mm aboveRRF-50 21 5713

Safety distances: minimum distances between the heater and combustible materials.

Standard

EN 15250:2007: slow heat release appliances fired by solid fuel, for domestic heating. It applies to all the heat-storing stoves in the range.

Declaration of performance (DoP)

The manufacturer’s document stating the declared performance of the appliance under the standard. Three declarations cover the range: RRF-50 21 5712 (Aida and Aino), RRF-50 21 5713 (Amanda and Sofia), RRF-50 23 6334 (Helmi and Heidi).

Built-in firewall (Sofia, Amanda)

The declaration of performance gives 50 mm at the back; the Finnish catalogue gives a rear safety distance of 0 mm for the version with a built-in firewall. This distance is not yet published in the French documentation: to be confirmed for each project.

AirBox

Ducted combustion air supply, available on Helmi and Heidi — earlier factory catalogues say otherwise and are out of date on this point.

Not yet published

  • Stored energy and heat release time of Aida and Aino: [TO BE CONFIRMED], the manufacturer’s sources disagree.
  • Nominal output of Sofia and Amanda: [OUTPUT: TO BE CONFIRMED].
  • Efficiency of the Heidi and safety distances of the Aino: [TO BE CONFIRMED].
  • Floor loads and supporting floor specification: no general specification. The load-bearing capacity of the floor or slab is assessed project by project.
  • Model specification clauses for a CCTP (cahier des clauses techniques particulières, the French technical specification in tender documents): available soon, on request in the meantime.

We would rather leave a box empty than publish a value not confirmed by the manufacturer.

Key points

  • Standard EN 15250:2007 across the whole range, three declarations of performance.
  • Built-in firewall on Sofia and Amanda; AirBox available on Helmi and Heidi.
  • Supporting floor and conflicting values: assessed case by case.
Sources and verification
  • Weight, output, efficiency, safety distances, declaration of performance numbers: Tiileri France product reference sheet (09/09/2026), based on declarations of performance RRF-50 21 5712, RRF-50 21 5713 and RRF-50 23 6334 and the manufacturer’s price list.
  • Rear distance of 0 mm: Finnish catalogue of 01/01/2024, cited in the product reference sheet.
  • Standard, firewall, AirBox and values adopted: Tiileri France product reference sheet (09/09/2026), as used in the brief of 15/09/2026.
  • Page checked on 16/09/2026; translated on 25/09/2026.

Request documentation or a study